138 research outputs found

    Mixed Reality-Based Simulator for Training on Imageless Navigation Skills in Total Hip Replacement Procedures

    Get PDF
    Imageless navigation systems (INS) in orthopaedics have been used to improve the outcomes of several orthopaedic procedures such as total hip replacement [1, 2]. However, the increased surgical times and the associate learning curve discourage surgeons from using navigation systems in their theatres [2]. This paper presents a Mixed Reality (MR) simulator that helps surgeons acquire the infrared based navigation skills before performing it in reality. A group of 7 hip surgeons tried the application, expressing their satisfaction with all the features and confirmed that the simulator represents a cheaper and faster option to train surgeons in the use of INS than the current learning methods

    Revision total hip arthroplasty using the Zweymuller femoral stem

    Get PDF
    Background: A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape, tapered-stem design at medium and long-term follow-up. Materials and methods: We performed a retrospective review of clinical and radiographic outcomes of twenty-eight consecutive femoral revisions arthroplasties, which were done using the Zweymuller femoral stem. Results: The mean follow-up was 7.4 years (range 2-15 years). No stem re-revision was necessary. All stems were judged to be stable by radiographic criteria at the most recent follow-up. The final mean Harris hip score was 90. There was no difference in Harris hip scores, implant stability, or radiological appearance (distal cortical hypertrophy or proximal stress shielding) of the implants between medium-term (mean 5.7 years) and long-term (mean 12.4 years) follow-up. Conclusions: We found the Zweymuller femoral stem design to be durable for revision hip arthroplasty when there is an intact metaphyseal-diaphyseal junction for adequate press-fit stability at surgery. © Springer-Verlag 2008

    Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

    Get PDF
    BACKGROUND: Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. METHODS: Twenty-four cadaveric femoral specimens were implanted with a fully porous-coated stem. Two different diameters were tested and the stems were implanted at multiple contact lengths without proximal bone support. Each specimen underwent torsional testing to failure and rotational micromotion was measured at the implant-bone interface. RESULTS: The larger stem diameter demonstrated a greater torsional stability for a given length of cortical contact (p ≤ 0.05). Decreasing length of diaphyseal contact length was associated with less torsional stability. Torsional resistance was inconsistent at 2 cm of depth. CONCLUSION: Larger stem diameters frequently used in revisions may be associated with less diaphyseal contact length to achieve equivalent rotational stability compared to smaller diameter stems. Furthermore, a minimum of 3 cm or 4 cm of diaphyseal contact with a porous-coated stem should be achieved in proximal femoral bone deficiency and will likely be dependent on the stem diameter utilized at the time of surgery

    Impaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute: Good outcome in 43 patients followed for a mean of 2 years

    Get PDF
    Background and purpose One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous ceramic specifically designed for use in impaction grafting. BoneSave is 80% tricalcium phosphate and 20% hydroxyapatite. Previous in vitro and in vivo studies have yielded good results using mixtures of allograft and BoneSave, when compared with allograft alone. This study is the first reported human clinical trial of BoneSave in impaction grafting

    Bone and joint infections in adults: a comprehensive classification proposal

    Get PDF
    Ten currently available classifications were tested for their ability to describe a continuous cohort of 300 adult patients affected by bone and joint infections. Each classification only focused, on the average, on 1.3\u2009\ub1\u20090.4 features of a single clinical condition (osteomyelitis, implant-related infections, or septic arthritis), being able to classify 34.8\u2009\ub1\u200924.7% of the patients, while a comprehensive classification system could describe all the patients considered in the study. RESULT AND CONCLUSION: A comprehensive classification system permits more accurate classification of bone and joint infections in adults than any single classification available and may serve for didactic, scientific, and clinical purposes
    corecore